BVGSS - MIL-C-22750E ACTIVATOR, PART B, P/N UO-137

  • MSDS: BVGSS
  • Manufacturer: CRAWFORD LABS INC
  • Product Name: MIL-C-22750E ACTIVATOR, PART B, P/N UO-137
  • National Stock Number: 8010-01-316-3034
Product Identification

Product ID:MIL-C-22750E ACTIVATOR, PART B, P/N UO-137
MSDS Date:05/20/1994
FSC:8010
NIIN:01-316-3034
Kit Part:Y
MSDS Number: BVGSS

Responsible Party
CRAWFORD LABS, INC
4165 S EMERALD AVE
CHICAGO, IL 60609
US

Emergency Phone: 312-433-1307

Info Phone: 312-376-7132

Preparer: DAVID SCHMETTERER

Cage: 5V430

Contractor
CRAWFORD LABORATORIES, INC
CHICAGO, IL 60609 US

Telephone: 312-376-7132

Cage: 5V430

Ingredients

METHYL ETHYL KETONE (SARA III) (VAPOR PRESSURE 71.2 MM HG)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 58%

OSHA PEL 100 PPM

ACGIH TLV: 200 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


PHENYL CARBINOL

CAS: 100-51-6

RTECS: DN3150000

Fraction By Weight: 15%


BENZALDEHYDE (MAY BE CONTAINED [0.3%] AS AN IMPURITY IN

CAS: 100-52-7

RTECS: CU4375000


DIBENZYL ETHER (MAY BE CONTAINED [0.1%] AS AN IMPURITY IN

CAS: 103-50-4

RTECS: DQ6125000


HYDROQUINONE MONOMETHYL ETHER (MAY BE CONTAINED [0.025%] AS

CAS: 150-76-5

RTECS: SL7700000


REACTION PRODUCTS OF EPICHLOROHYDRIN & BISPHENOL A

CAS: 25085-99-8

Fraction By Weight: 7.0%


NH2CH2CH(CH3)(CH2)3NH2 (VAPOR PRESSURE 130 MM HG)

CAS: 15520-10-2

RTECS: SA0248500

Fraction By Weight: 18%

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:OVEREXPOSURE MAY PRODUCE VARIOUS
EFFECTS, INCLUDING: ACUTE TOXICITY (HEADACHE, DIZZINESS, NAUSEA,
UNCONSCIOUSNESS). SEVERE EYE IRRITATION (POSSIBLY PERMANENT
DAMAGE). IRRITATED MUCOUS MEMBRANES. VOMIT ING DUE TO INGESTION.
DEFATTING & DRYING OF SKIN. SENSITIZATION AFTER REPEATED CONTACT.

First Aid

First Aid:EYE:FLUSH W/LUKEWRM LOW PRESSR H2O 15 MIN,LIFT EYELID.GET MED
AID.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN IF BREATH DIFFICLT.GIVE
ARTIF RESP,IF NO BREATH.GET MED AID.KEEP WARM/COMFRTBL.NEVER GIVE
UNCONS CIOUS LIQ.INGEST:CALL DR IMMED.INDUCE VOMIT ON DR'S
INSTRCTN.IF VOMIT,KEEP HEAD BELOW HIP.NEVER GIVE ANYTHING TO
UNCONSCIOUS.SKIN:FLUSH W/H2O REMOVING CONTAM CLOTH.WASH
W/SOAP&H2O.GET MED AID IF IRRIT

Fire Fighting

Flash Point Method:SCC
Flash Point:22.0F,-5.6C
Lower Limits:2.
Extinguishing Media:FOAM, CO2, OR DRY CHEMICAL
Fire Fighting Procedures:WATER MAY BE USED TO COOL EXPOSED CONTAINER, &
TO KEEP FLAMMABLE STRUCTURES WET. DON'T ENTER FIRE AREA WITHOUT
PROTECTION BECAUSE DECOMP PRODUCT MAY BE PRESENT.
Unusual Fire/Explosion Hazard:WATER PRESSURE MAY SPREAD A FLAMMABLE
LIQUID FIRE. SEALED CONTAINERS MAY EXPLODE IF OVERHEATED.

Accidental Release

Spill Release Procedures:WARNING - FLAMMABLE. ELIMINATE ALL IGNITION
SOURCES. HANDLING EQUIPMENT MUST BE GROUNDED TO PREVENT SPARKING.
SOAK UP WITH AN ABSORBENT AND PLACE IN NON-LEAKING CONTAINERS. SEAL
TIGHTLY FOR PROPER DIS POSAL.

Handling

Handling and Storage Precautions:FLAMMABLE. KNOW DOT REGS BEFORE
TRANSPORTING.WARNING:HOT ORGANIC CHEMICAL VAPOR OR MIST SUSCEPTIBLE
TO SUDDEN SPONTANEOUS COMBUSTION WHEN MIXED W/AIR.
Other Precautions:IGNIT MAY OCCUR AT TEMP BELOW AUTOIGNIT/IGNIT
TEMPS.IGNIT TEMPS DECREASE W/INCREASING VAPOR VOLUME & VAPOR/AIR
CONTACT TIME & INFLUENCED BY PRESSR CHANGE.IGNIT MAY OCCUR AT
ELEVATED TEMP,ESPECIALLY IN VACUUM IF SUDDEN INGRESS AIR OR *

Exposure Controls

Respiratory Protection:IMPORTANT-MUST PROVIDE ADEQUATE VENTILATION TO
MAINTAIN VAPOR CONCENTRATIONS BELOW ESTABLISHED TLV LIMIT AS GIVEN
BY OSHA. IN MORE CONFINED AREAS NIOSH-MSHA APPROVED RESPIRATOR
EQUIPPED WITH ORGANIC V APOR CARTRIDGE SHOULD BE WORN.
Ventilation:MUST PROVIDE ADEQUATE VENTILATION. SEE PARAGRAPH ON
RESPIRATORY PROTECTION.
Protective Gloves:USE RUBBER GLOVES.
Eye Protection:WEAR APPROVED SAFETY GOGGLES OR FACESHLD
Other Protective Equipment:HAVE EYE BATH AND SAFETY SHOWER AVAILABLE.
Work Hygienic Practices:DO NOT REUSE CONTAMINATED CLOTHING OR SHOES.
Supplemental Safety and Health
* OUTSIDE PROCESS EQUIPMENT OPERATING UNDER ELEVATED PRESSURE IF SUDDEN
ESCAPE OF VAPOR OR MIST TO THE ATMOSPHERE OCCURS. ANY PROPOSED USE
SHOULD BE THOROUGHLY EVALUATED TO ASSURE THAT SAFE OPERATING
CONDITIONS ARE ESTABLISHED AND MAINTAINED.

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:174 TO 401F
Vapor Density:> AIR
Spec Gravity:0.86
Viscosity:65 KU
Evaporation Rate & Reference:3.64 X N-BU AC
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR LIQUID / SOLVENT ODOR
Percent Volatiles by Volume:79.9
Corrosion Rate:NOT CORR

Stability

Stability Indicator/Materials to Avoid:YES
MAY BE INCOMPATIBLE WITH OXIDIZING AGENT AND STRONG ALKALIES.
Stability Condition to Avoid:AVOID HEAT, SPARKS, AND OPEN FLAMES.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION FOR PRODUCTS
LIKE THIS MAY GENERATE HIGH POISONOUS CARBON MONOXIDE AND OTHER
TOXIC GASES.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH CURRENT
LOCAL, STATE, AND FEDERAL REGULATION. CONTACT AN APPROVED DISPOSAL
FACILITY. EPA HAZARDOUS WASTE CODE: D001, IGNITABLE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.